2 Hour 1 Hour Fire Rated Wall Assembly

Head of wall firestop system gypsum board fire trak shadowline.
2 hour 1 hour fire rated wall assembly. These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies. Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system incorporating the product or any given piece of the product. Descriptions of successfully tested i joist floor as. Use special fiberglass rated for use in firewalls.
Ul design u499 w419. American softwood lumber standard ps 20. Lumber shall be identified by the grade mark of a lumber grading or inspection agency that has been approved by an accreditation body that complies with the. Mount a 1 1 2 inch fiberglass barrier inside the studs.
Assembly ff file no. Use steel studs and two layers of 1 2 inch type c drywall on each side of the studs for a two hour fire rating on an interior wall. According to the engineered wood association a one hour rating indicates that a wall constructed in a manner similar to the one tested will contain flames and high temperatures and support its full load for at least one hour after the fire begins. Sw 106 1 hour shaftwall with deflection track.
Table 1 for one hour rated wall assemblies and table 2 for two hour rated wall assemblies. Also cites circumstances requiring 1 and 2 hour rated walls and until now typical rated wood frame stud walls have been used to meet those needs. Elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies. Commonly used fire rated designs for stud walls are ul u309 a 1 hour assembly and ul u301 a 2 hour assembly ul 2013a 2013b.
A portion of the building has 2 hour load bearing walls with 1 hour walls stacked on top. 2 x 4 f d 24 o c shear wall 1 2 plywood common wall 7 8 redwood roxul mineral wool batts finish wall 3 4 plywood. Fire resistance ratings are expressed in the number of minutes or hours a structure can withstand a fire simulation test. The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels.
2 x 6 wood studs 16 o c 3 4 plywood.